Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Built-in depth72mm
Rated current6A
Rated insulation voltage Ui440V
Voltage typeAC
Rated voltage230V
Rated fault current0.3A
Number of protected poles2
Frequency50 Hz
Leakage current typeA
Degree of protection (IP)IP20
Power loss3.04W
Connectable conductor cross section multi-wired1 - 25mm²
Current limiting class3
Pollution degree3
Rated short-circuit breaking capacity according to IEC 60947-210kA
Width in number of modular spacings2
Concurrently switching neutral conductorYes
Over voltage category3
Surge current capacity0.25kA
Connectable conductor cross section solid-core- - -mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR752140R3064 | DS202CR C6 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Built-in depth

72mm

Rated current

6A

Rated insulation voltage Ui

440V

Voltage type

AC

Rated voltage

230V

Rated fault current

0.3A

Number of protected poles

2

Frequency

50 Hz

Leakage current type

A

Degree of protection (IP)

IP20

Power loss

3.04W

Connectable conductor cross section multi-wired

1 .. 25mm²

Current limiting class

3

Pollution degree

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Width in number of modular spacings

2

Concurrently switching neutral conductor

Over voltage category

3

Surge current capacity

0.25kA

Connectable conductor cross section solid-core

- .. -mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.