Technical specifications

Voltage typeAC
Built-in depth72mm
Rated current6A
Release characteristicB
Rated voltage230V
Rated insulation voltage Ui440V
Rated fault current0.3A
Width in number of modular spacings2
Leakage current typeA
Current limiting class3
Over voltage category3
Surge current capacity0.25kA
Pollution degree3
Frequency50 Hz
Degree of protection (IP)IP20
Number of protected poles2
Power loss3.04W
Concurrently switching neutral conductorYes
With interlocking deviceNo
Connectable conductor cross section multi-wired1 - 25mm²
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Connectable conductor cross section solid-core- - -mm²
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of poles (total)2
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR752140R3065 | DS202CR B6 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

72mm

Rated current

6A

Release characteristic

B

Rated voltage

230V

Rated insulation voltage Ui

440V

Rated fault current

0.3A

Width in number of modular spacings

2

Leakage current type

A

Current limiting class

3

Over voltage category

3

Surge current capacity

0.25kA

Pollution degree

3

Frequency

50 Hz

Degree of protection (IP)

IP20

Number of protected poles

2

Power loss

3.04W

Concurrently switching neutral conductor

With interlocking device

Connectable conductor cross section multi-wired

1 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Connectable conductor cross section solid-core

- .. -mm²

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of poles (total)

2

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA