Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth72mm
Release characteristicB
Rated insulation voltage Ui440V
Voltage typeAC
Rated voltage230V
Current limiting class3
Surge current capacity0.25kA
Frequency50 Hz
Pollution degree3
Over voltage category3
Width in number of modular spacings2
Power loss5.04W
With interlocking deviceNo
Connectable conductor cross section solid-core- - -mm²
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 55°C
Number of protected poles2
Connectable conductor cross section multi-wired1 - 25mm²
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to IEC 60947-210kA
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated short-circuit breaking capacity according to EN 610096kA
Flush-mounted installationNo
Rated current20A
Rated fault current0.3A
Leakage current typeA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR752140R3205 | DS202CR B20 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

72mm

Release characteristic

B

Rated insulation voltage Ui

440V

Voltage type

AC

Rated voltage

230V

Current limiting class

3

Surge current capacity

0.25kA

Frequency

50 Hz

Pollution degree

3

Over voltage category

3

Width in number of modular spacings

2

Power loss

5.04W

With interlocking device

Connectable conductor cross section solid-core

- .. -mm²

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 55°C

Number of protected poles

2

Connectable conductor cross section multi-wired

1 .. 25mm²

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Flush-mounted installation

Rated current

20A

Rated fault current

0.3A

Leakage current type

A

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.