Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated voltage230V
Rated fault current0.01A
Rated insulation voltage Ui440V
Release characteristicB
Built-in depth72mm
Surge current capacity0.25kA
Rated current13A
Connectable conductor cross section solid-core- - -mm²
Degree of protection (IP)IP20
Number of protected poles2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Power loss3.74W
Connectable conductor cross section multi-wired1 - 25mm²
Leakage current typeA
Width in number of modular spacings2
Current limiting class3
Frequency50 Hz
With interlocking deviceNo
Over voltage category3
Concurrently switching neutral conductorYes
Pollution degree3
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772140R0135 | DS202CR M B13 A10

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated voltage

230V

Rated fault current

0.01A

Rated insulation voltage Ui

440V

Release characteristic

B

Built-in depth

72mm

Surge current capacity

0.25kA

Rated current

13A

Connectable conductor cross section solid-core

- .. -mm²

Degree of protection (IP)

IP20

Number of protected poles

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Power loss

3.74W

Connectable conductor cross section multi-wired

1 .. 25mm²

Leakage current type

A

Width in number of modular spacings

2

Current limiting class

3

Frequency

50 Hz

With interlocking device

Over voltage category

3

Concurrently switching neutral conductor

Pollution degree

3

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.