Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Built-in depth72mm
Rated current6A
Release characteristicC
Rated voltage230V
Connectable conductor cross section solid-core- - -mm²
Rated insulation voltage Ui440V
Rated fault current0.03A
Power loss3.04W
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorYes
Width in number of modular spacings2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Current limiting class3
Degree of protection (IP)IP20
Frequency50 Hz
Over voltage category3
Number of protected poles2
Pollution degree3
Surge current capacity0.25kA
Leakage current typeA
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C
Anti-nuisance tripping versionNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772140R1064 | DS202CR M C6 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

72mm

Rated current

6A

Release characteristic

C

Rated voltage

230V

Connectable conductor cross section solid-core

- .. -mm²

Rated insulation voltage Ui

440V

Rated fault current

0.03A

Power loss

3.04W

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Current limiting class

3

Degree of protection (IP)

IP20

Frequency

50 Hz

Over voltage category

3

Number of protected poles

2

Pollution degree

3

Surge current capacity

0.25kA

Leakage current type

A

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

Anti-nuisance tripping version

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.