Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristicB
Built-in depth72mm
Rated insulation voltage Ui440V
Rated voltage230V
Surge current capacity0.25kA
Voltage typeAC
Power loss3.04W
Current limiting class3
Width in number of modular spacings2
Pollution degree3
Over voltage category3
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated impulse withstand voltage Uimp4kV
With interlocking deviceNo
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Number of protected poles2
Frequency50 Hz
Rated short-circuit breaking capacity according to EN 6100910kA
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core- - -mm²
Disconnection characteristicUndelayed
Degree of protection (IP)IP20
Anti-nuisance tripping versionNo
Rated current6A
Rated fault current0.03A
Leakage current typeA
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772140R1065 | DS202CR M B6 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

B

Built-in depth

72mm

Rated insulation voltage Ui

440V

Rated voltage

230V

Surge current capacity

0.25kA

Voltage type

AC

Power loss

3.04W

Current limiting class

3

Width in number of modular spacings

2

Pollution degree

3

Over voltage category

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated impulse withstand voltage Uimp

4kV

With interlocking device

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Number of protected poles

2

Frequency

50 Hz

Rated short-circuit breaking capacity according to EN 61009

10kA

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

- .. -mm²

Disconnection characteristic

Undelayed

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Rated current

6A

Rated fault current

0.03A

Leakage current type

A

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.