Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductorYes
Pollution degree3
Width in number of modular spacings2
Voltage typeAC
Power loss5.04W
Number of protected poles2
Rated insulation voltage Ui440V
Current limiting class3
Built-in depth72mm
Rated fault current0.03A
Rated current20A
Frequency50 Hz
Surge current capacity0.25kA
Release characteristicB
Degree of protection (IP)IP20
Leakage current typeA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated voltage230V
Over voltage category3
Connectable conductor cross section multi-wired1 - 25mm²
Connectable conductor cross section solid-core- - -mm²
Flush-mounted installationNo
Disconnection characteristicUndelayed
Ambient temperature during operating-25 - 55°C
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
With interlocking deviceNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772140R1205 | DS202CR M B20 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductor

Pollution degree

3

Width in number of modular spacings

2

Voltage type

AC

Power loss

5.04W

Number of protected poles

2

Rated insulation voltage Ui

440V

Current limiting class

3

Built-in depth

72mm

Rated fault current

0.03A

Rated current

20A

Frequency

50 Hz

Surge current capacity

0.25kA

Release characteristic

B

Degree of protection (IP)

IP20

Leakage current type

A

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated voltage

230V

Over voltage category

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Connectable conductor cross section solid-core

- .. -mm²

Flush-mounted installation

Disconnection characteristic

Undelayed

Ambient temperature during operating

-25 .. 55°C

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

With interlocking device

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.