Aleta.hr
Main Product Image

2CSR772140R1255 | DS202CR M B25 A30

Code: 2004311

ManufacturerABB
Catalog number2CSR772140R1255
EAN code4022903034575

















Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Leakage current typeA
Rated current25A
Number of protected poles2
Number of poles (total)2
Rated voltage230V
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity according to IEC 60947-210kA
Power loss6.20W
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Voltage typeAC
Current limiting class3
Surge current capacity0.25kA
Rated fault current0.03A
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed
Frequency50 Hz
Concurrently switching neutral conductorYes
Degree of protection (IP)IP20
With interlocking deviceNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core- - -mm²
Release characteristicB
Built-in depth72mm
Anti-nuisance tripping versionNo
Pollution degree3
Connectable conductor cross section multi-wired1 - 25mm²
Flush-mounted installationNo
Over voltage category3
Width in number of modular spacings2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772140R1255 | DS202CR M B25 A30

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Leakage current type

A

Rated current

25A

Number of protected poles

2

Number of poles (total)

2

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Power loss

6.20W

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Voltage type

AC

Current limiting class

3

Surge current capacity

0.25kA

Rated fault current

0.03A

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed

Frequency

50 Hz

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

- .. -mm²

Release characteristic

B

Built-in depth

72mm

Anti-nuisance tripping version

Pollution degree

3

Connectable conductor cross section multi-wired

1 .. 25mm²

Flush-mounted installation

Over voltage category

3

Width in number of modular spacings

2