Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current10A
Built-in depth72mm
Voltage typeAC
Width in number of modular spacings2
Rated insulation voltage Ui440V
Release characteristicB
Power loss3.28W
Rated voltage230V
Rated fault current0.3A
Surge current capacity0.25kA
Degree of protection (IP)IP20
Pollution degree3
Current limiting class3
Frequency50 Hz
Over voltage category3
Leakage current typeA
Number of protected poles2
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
With interlocking deviceNo
Number of poles (total)2
Rated short-circuit breaking capacity according to EN 6100910kA
Disconnection characteristicUndelayed
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772140R3105 | DS202CR M B10 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current

10A

Built-in depth

72mm

Voltage type

AC

Width in number of modular spacings

2

Rated insulation voltage Ui

440V

Release characteristic

B

Power loss

3.28W

Rated voltage

230V

Rated fault current

0.3A

Surge current capacity

0.25kA

Degree of protection (IP)

IP20

Pollution degree

3

Current limiting class

3

Frequency

50 Hz

Over voltage category

3

Leakage current type

A

Number of protected poles

2

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

With interlocking device

Number of poles (total)

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Disconnection characteristic

Undelayed

Anti-nuisance tripping version

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.