Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Over voltage category3
Rated current13A
Surge current capacity0.25kA
Built-in depth72mm
Leakage current typeA
Frequency50 Hz
Width in number of modular spacings2
Current limiting class3
Pollution degree3
Power loss3.74W
Degree of protection (IP)IP20
Rated fault current0.3A
Rated insulation voltage Ui440V
Number of protected poles2
Release characteristicC
Flush-mounted installationNo
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 55°C
With interlocking deviceNo
Rated voltage230V
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of poles (total)2
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired1 - 25mm²
Concurrently switching neutral conductorYes
Disconnection characteristicUndelayed
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772140R3134 | DS202CR M C13 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Over voltage category

3

Rated current

13A

Surge current capacity

0.25kA

Built-in depth

72mm

Leakage current type

A

Frequency

50 Hz

Width in number of modular spacings

2

Current limiting class

3

Pollution degree

3

Power loss

3.74W

Degree of protection (IP)

IP20

Rated fault current

0.3A

Rated insulation voltage Ui

440V

Number of protected poles

2

Release characteristic

C

Flush-mounted installation

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 55°C

With interlocking device

Rated voltage

230V

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of poles (total)

2

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Concurrently switching neutral conductor

Disconnection characteristic

Undelayed

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.