Aleta.hr
Main Product Image

2CSR772198R1405 | DS202CR M B40 A30 50/60

Code: 2004347

ManufacturerABB
Catalog number2CSR772198R1405
EAN code4022903035053

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth72mm
Rated current40A
Voltage typeAC
Current limiting class3
Rated voltage230V
Over voltage category3
Power loss8.92W
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Width in number of modular spacings2
Rated fault current0.03A
Release characteristicC
Leakage current typeA
Pollution degree3
Frequency50/60 Hz
Surge current capacity0.25kA
Number of protected poles2
Rated short-circuit breaking capacity according to IEC 60947-210kA
Connectable conductor cross section solid-core- - -mm²
Concurrently switching neutral conductorYes
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity according to EN 6100910kA
Connectable conductor cross section multi-wired1 - 25mm²
Anti-nuisance tripping versionNo
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
With interlocking deviceNo
Rated impulse withstand voltage Uimp4kV
Number of poles (total)2
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772198R1405 | DS202CR M B40 A30 50/60

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

72mm

Rated current

40A

Voltage type

AC

Current limiting class

3

Rated voltage

230V

Over voltage category

3

Power loss

8.92W

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Rated fault current

0.03A

Release characteristic

C

Leakage current type

A

Pollution degree

3

Frequency

50/60 Hz

Surge current capacity

0.25kA

Number of protected poles

2

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Connectable conductor cross section solid-core

- .. -mm²

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity according to EN 61009

10kA

Connectable conductor cross section multi-wired

1 .. 25mm²

Anti-nuisance tripping version

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Disconnection characteristic

Undelayed

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.