Aleta.hr
Main Product Image

2CSR772199R1324 | DS202CR M C32 A30 110V

Code: 2004353

ManufacturerABB
Catalog number2CSR772199R1324
EAN code4022903035138

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Built-in depth72mm
Release characteristicC
Concurrently switching neutral conductorYes
Rated fault current0.03A
Voltage typeAC
Rated current32A
Rated voltage110V
Surge current capacity0.25kA
Leakage current typeA
Pollution degree3
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-210kA
Number of protected poles2
Current limiting class3
Power loss7.60W
Over voltage category3
Width in number of modular spacings2
Degree of protection (IP)IP20
With interlocking deviceNo
Connectable conductor cross section solid-core- - -mm²
Connectable conductor cross section multi-wired1 - 25mm²
Number of poles (total)2
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Rated short-circuit breaking capacity according to EN 6100910kA
Rated impulse withstand voltage Uimp4kV
Disconnection characteristicUndelayed
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772199R1324 | DS202CR M C32 A30 110V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Built-in depth

72mm

Release characteristic

C

Concurrently switching neutral conductor

Rated fault current

0.03A

Voltage type

AC

Rated current

32A

Rated voltage

110V

Surge current capacity

0.25kA

Leakage current type

A

Pollution degree

3

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Number of protected poles

2

Current limiting class

3

Power loss

7.60W

Over voltage category

3

Width in number of modular spacings

2

Degree of protection (IP)

IP20

With interlocking device

Connectable conductor cross section solid-core

- .. -mm²

Connectable conductor cross section multi-wired

1 .. 25mm²

Number of poles (total)

2

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Anti-nuisance tripping version

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed