Aleta.hr
Main Product Image

2CSR772199R1404 | DS202CR M C40 A30 110V

Code: 2004354

ManufacturerABB
Catalog number2CSR772199R1404
EAN code4022903035145

















Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles2
Rated voltage110V
Rated current40A
Number of poles (total)2
Rated fault current0.03A
Current limiting class3
Leakage current typeA
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 6100910kA
Power loss8.92W
Rated short-circuit breaking capacity according to IEC 60947-210kA
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Surge current capacity0.25kA
Voltage typeAC
Frequency50/60 Hz
Built-in depth72mm
Ambient temperature during operating-25 - 55°C
Pollution degree3
With interlocking deviceNo
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Release characteristicC
Connectable conductor cross section multi-wired1 - 25mm²
Degree of protection (IP)IP20
Over voltage category3
Anti-nuisance tripping versionNo
Width in number of modular spacings2
Connectable conductor cross section solid-core- - -mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772199R1404 | DS202CR M C40 A30 110V

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

2

Rated voltage

110V

Rated current

40A

Number of poles (total)

2

Rated fault current

0.03A

Current limiting class

3

Leakage current type

A

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

8.92W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Surge current capacity

0.25kA

Voltage type

AC

Frequency

50/60 Hz

Built-in depth

72mm

Ambient temperature during operating

-25 .. 55°C

Pollution degree

3

With interlocking device

Concurrently switching neutral conductor

Flush-mounted installation

Release characteristic

C

Connectable conductor cross section multi-wired

1 .. 25mm²

Degree of protection (IP)

IP20

Over voltage category

3

Anti-nuisance tripping version

Width in number of modular spacings

2

Connectable conductor cross section solid-core

- .. -mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.