Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth72mm
Voltage typeAC
Power loss3.04W
Over voltage category3
Number of protected poles2
Leakage current typeA
Current limiting class3
Degree of protection (IP)IP20
Surge current capacity3kA
Frequency50 Hz
Pollution degree3
Rated current6A
Release characteristicB
Width in number of modular spacings2
Rated voltage230V
Rated fault current0.03A
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Concurrently switching neutral conductorYes
Disconnection characteristicUndelayed
With interlocking deviceNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core- - -mm²
Number of poles (total)2
Anti-nuisance tripping versionYes
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section multi-wired1 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772440R1065 | DS202CR M B6 APR30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

72mm

Voltage type

AC

Power loss

3.04W

Over voltage category

3

Number of protected poles

2

Leakage current type

A

Current limiting class

3

Degree of protection (IP)

IP20

Surge current capacity

3kA

Frequency

50 Hz

Pollution degree

3

Rated current

6A

Release characteristic

B

Width in number of modular spacings

2

Rated voltage

230V

Rated fault current

0.03A

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Concurrently switching neutral conductor

Disconnection characteristic

Undelayed

With interlocking device

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

- .. -mm²

Number of poles (total)

2

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section multi-wired

1 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA