Aleta.hr
Main Product Image

2CSR772440R1255 | DS202CR M B25 APR30

Code: 2004366

ManufacturerABB
Catalog number2CSR772440R1255
EAN code4022903035305

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated insulation voltage Ui440V
Built-in depth72mm
Release characteristicB
Rated voltage230V
Rated current25A
Leakage current typeA
Rated fault current0.03A
Connectable conductor cross section multi-wired1 - 25mm²
Pollution degree3
Frequency50 Hz
Disconnection characteristicUndelayed
Degree of protection (IP)IP20
Anti-nuisance tripping versionYes
Number of protected poles2
Width in number of modular spacings2
With interlocking deviceNo
Rated impulse withstand voltage Uimp4kV
Surge current capacity3kA
Rated short-circuit breaking capacity according to IEC 60947-210kA
Over voltage category3
Number of poles (total)2
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity according to EN 6100910kA
Power loss6.20W
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Flush-mounted installationNo
Connectable conductor cross section solid-core- - -mm²
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR772440R1255 | DS202CR M B25 APR30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated insulation voltage Ui

440V

Built-in depth

72mm

Release characteristic

B

Rated voltage

230V

Rated current

25A

Leakage current type

A

Rated fault current

0.03A

Connectable conductor cross section multi-wired

1 .. 25mm²

Pollution degree

3

Frequency

50 Hz

Disconnection characteristic

Undelayed

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Number of protected poles

2

Width in number of modular spacings

2

With interlocking device

Rated impulse withstand voltage Uimp

4kV

Surge current capacity

3kA

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Over voltage category

3

Number of poles (total)

2

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity according to EN 61009

10kA

Power loss

6.20W

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Flush-mounted installation

Connectable conductor cross section solid-core

- .. -mm²

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.