Aleta.hr

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Construction size3 modular spacing
Mounting methodOther
Nominal voltage DC15000V
Max. continuous voltage AC1500V
With remote signalling contactNo
Voltage protection level4kV
Category type 2Yes
Number of conductors (without earthing)2
Voltage protection level L-N-kV
Nominal discharge surge current (8/20)20kA
Nominal voltage AC-V
Leakage-current freeNo
Voltage protection level N-PE-kV
Max. conductor cross section flexible (fine-strand)25mm²
Max. overcurrent protection device, series connection (fuse)-A
Degree of protection (IP)IP20
Max. overcurrent protection device, parallel connection (fuse)-A
System configuration ITNo
System configuration TTNo
Integrated short-circuit protectionNo
System configuration otherNo
Integrated short-circuit protection selective to fuse gG-A
Max. conductor cross section solid (solid, stranded)35mm²
System configuration DCYes
Short-circuit breaking capacity (Isccr)10kA
Integrated backup fuseNo
Max. PV-voltage1500V
System configuration TN-CNo
Max. discharge surge current (8/20)20kA
System configuration TNNo
System configuration TN-C-SNo
Max. continuous voltage DC1500V
System configuration TN-SNo
Signalling at the deviceOptic
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CTB802401R1500 | OVR PV T2 40-1500 P TS

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Earthing, lightning and surge protection
  • Surge protection device for power supply systems
  • 1 KOM
  • ABB

Technical specifications

Construction size

3 modular spacing

Mounting method

Other

Nominal voltage DC

15000V

Max. continuous voltage AC

1500V

With remote signalling contact

Voltage protection level

4kV

Category type 2

Number of conductors (without earthing)

2

Voltage protection level L-N

-kV

Nominal discharge surge current (8/20)

20kA

Nominal voltage AC

-V

Leakage-current free

Voltage protection level N-PE

-kV

Max. conductor cross section flexible (fine-strand)

25mm²

Max. overcurrent protection device, series connection (fuse)

-A

Degree of protection (IP)

IP20

Max. overcurrent protection device, parallel connection (fuse)

-A

System configuration IT

System configuration TT

Integrated short-circuit protection

System configuration other

Integrated short-circuit protection selective to fuse gG

-A

Max. conductor cross section solid (solid, stranded)

35mm²

System configuration DC

Short-circuit breaking capacity (Isccr)

10kA

Integrated backup fuse

Max. PV-voltage

1500V

System configuration TN-C

Max. discharge surge current (8/20)

20kA

System configuration TN

System configuration TN-C-S

Max. continuous voltage DC

1500V

System configuration TN-S

Signalling at the device

Optic

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.