Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- ABB
Technical specifications
System configuration DC
Yes
System configuration TN
No
System configuration other
No
System configuration IT
No
System configuration TN-C
No
System configuration TN-S
No
System configuration TN-C-S
No
System configuration TT
No
Number of conductors (without earthing)
2
Max. discharge surge current (8/20)
20kA
Nominal discharge surge current (8/20)
20kA
Max. continuous voltage AC
1500V
Nominal voltage AC
-V
Max. continuous voltage DC
1500V
Nominal voltage DC
1500V
Max. PV-voltage
1500V
Voltage protection level
4kV
Voltage protection level L-N
-kV
Max. overcurrent protection device, parallel connection (fuse)
-A
Short-circuit breaking capacity (Isccr)
10kA
Integrated short-circuit protection
No
Max. overcurrent protection device, series connection (fuse)
-A
Leakage-current free
No
Integrated short-circuit protection selective to fuse gG
-A
Construction size
1 modular spacing
Mounting method
Other
Max. conductor cross section solid (solid, stranded)
35mm²
Integrated backup fuse
No
Max. conductor cross section flexible (fine-strand)
25mm²
Voltage protection level N-PE
-kV
With remote signalling contact
No
Degree of protection (IP)
IP20
Signalling at the device
Optic
Category type 2
Yes
From same serie
2CTB802402R1500 | OVR PV T2 40-1500 C

Details
- Earthing, lightning and surge protection
- Surge protection device for power supply systems
- 1 KOM
- ABB
Technical specifications
System configuration DC
System configuration TN
System configuration other
System configuration IT
System configuration TN-C
System configuration TN-S
System configuration TN-C-S
System configuration TT
Number of conductors (without earthing)
2
Max. discharge surge current (8/20)
20kA
Nominal discharge surge current (8/20)
20kA
Max. continuous voltage AC
1500V
Nominal voltage AC
-V
Max. continuous voltage DC
1500V
Nominal voltage DC
1500V
Max. PV-voltage
1500V
Voltage protection level
4kV
Voltage protection level L-N
-kV
Max. overcurrent protection device, parallel connection (fuse)
-A
Short-circuit breaking capacity (Isccr)
10kA
Integrated short-circuit protection
Max. overcurrent protection device, series connection (fuse)
-A
Leakage-current free
Integrated short-circuit protection selective to fuse gG
-A
Construction size
1 modular spacing
Mounting method
Other
Max. conductor cross section solid (solid, stranded)
35mm²
Integrated backup fuse
Max. conductor cross section flexible (fine-strand)
25mm²
Voltage protection level N-PE
-kV
With remote signalling contact
Degree of protection (IP)
IP20
Signalling at the device
Optic
Category type 2