Number of outputs, safety related, undelayed, with contact4
Number of outputs, signalling function, delayed, with contact0
Number of outputs, signalling function, undelayed, semiconductors0
Number of outputs, safety related, undelayed, semiconductors0
Number of outputs, signalling function, delayed, semiconductors0
Number of outputs, signalling function, undelayed, with contact0
With detachable clampsYes
Number of outputs, safety related, delayed, with contact0
With approval according to ULYes
Number of outputs, safety related, delayed, semiconductors0
Suitable for monitoring of proximity switchesYes
Stop category according to IEC 602040
Suitable for monitoring of position switchesYes
Type of electric connectionOther
Suitable for monitoring of magnetic switchesYes
SIL according to IEC 615083
With approval for BG BIANo
Rail mounting possibleYes
Suitable for monitoring of tactile sensorsNo
Suitable for monitoring of optoelectronic protection equipmentNo
Evaluation inputsOne- and two-channel
Suitable for monitoring of valvesYes
Suitable for monitoring of emergency-stop circuitsYes
Voltage type for actuatingDC
Rated control supply voltage Us at DC24 - 24V
Type of safety according to IEC 61496-1None
Performance level according to EN ISO 13849-1Level e