Aleta.hr

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformerNo
Width45mm
Depth154mm
Height200mm
Power consumption2.6W
Number of auxiliary contacts as normally closed contact0
Number of command positions0
Rated operation current Ie8.5A
Number of auxiliary contacts as normally open contact1
Overload release current setting6.3 - 10A
Supporting protocol for LONNo
Suitable for emergency stopNo
Rated operation power at AC-3, 400 V4kW
Supporting protocol for TCP/IPNo
Supporting protocol for CANNo
Supporting protocol for PROFIBUSNo
Supporting protocol for SUCONETNo
Supporting protocol for ModbusNo
Supporting protocol for DeviceNetNo
Rail mounting possibleNo
Supporting protocol for Data-HighwayNo
External reset possibleNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for other bus systemsNo
Rated control supply voltage Us at DC24 - 24V
Rated control supply voltage Us at AC 60HZ0 - 0V
Rated control supply voltage Us at AC 50HZ0 - 0V
Number of indicator lights0
Type of electrical connection of main circuitScrew connection
With fuseNo
Supporting protocol for INTERBUS-SafetyNo
Type of electrical connection for auxiliary- and control current circuitScrew connection
With short-circuit releaseYes
Supporting protocol for AS-Interface Safety at WorkNo
Release classCLASS 10 A
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for SERCOSNo
Degree of protection (IP)IP20
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingDC
Supporting protocol for PROFINET IONo
Rated operation power at AC-3, 230 V, 3-phase2.2kW
Type of motor starterDirect online starter (DOL)
Rated power, 575 V, 60 Hz, 3-phase0kW
Rated power, 460 V, 60 Hz, 3-phase0kW
Rated operation current at AC-3, 400 V9A
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFIsafeNo
Rated conditional short-circuit current, type 2, 400 V100A
Temperature compensated overload protectionYes
Ambient temperature, upper operating limit55°C
Rated conditional short-circuit current, type 1, 480 Y/277 V0A
Degree of protection (NEMA)Other
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 1, 600 Y/347 V0A
Rated conditional short-circuit current, type 2, 230 V0A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

MSC-D-10-M9(24VDC)/BBA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

With transformer

Width

45mm

Depth

154mm

Height

200mm

Power consumption

2.6W

Number of auxiliary contacts as normally closed contact

0

Number of command positions

0

Rated operation current Ie

8.5A

Number of auxiliary contacts as normally open contact

1

Overload release current setting

6.3 .. 10A

Supporting protocol for LON

Suitable for emergency stop

Rated operation power at AC-3, 400 V

4kW

Supporting protocol for TCP/IP

Supporting protocol for CAN

Supporting protocol for PROFIBUS

Supporting protocol for SUCONET

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Rail mounting possible

Supporting protocol for Data-Highway

External reset possible

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for other bus systems

Rated control supply voltage Us at DC

24 .. 24V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated control supply voltage Us at AC 50HZ

0 .. 0V

Number of indicator lights

0

Type of electrical connection of main circuit

Screw connection

With fuse

Supporting protocol for INTERBUS-Safety

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With short-circuit release

Supporting protocol for AS-Interface Safety at Work

Release class

CLASS 10 A

Supporting protocol for DeviceNet Safety

Supporting protocol for SERCOS

Degree of protection (IP)

IP20

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Voltage type for actuating

DC

Supporting protocol for PROFINET IO

Rated operation power at AC-3, 230 V, 3-phase

2.2kW

Type of motor starter

Direct online starter (DOL)

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

9A

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFIsafe

Rated conditional short-circuit current, type 2, 400 V

100A

Temperature compensated overload protection

Ambient temperature, upper operating limit

55°C

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Degree of protection (NEMA)

Other

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.