Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Yes
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated control supply voltage Us at AC 50HZ
0 - 0V
Voltage type for actuating
DC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Ambient temperature, upper operating limit
55°C
Rated control supply voltage Us at DC
24 - 24V
Power consumption
2.6W
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation power at AC-3, 400 V
4kW
Rated operation current Ie
8.5A
Rated conditional short-circuit current, type 2, 400 V
100A
Number of auxiliary contacts as normally open contact
1
Number of command positions
0
Release class
CLASS 10 A
Number of auxiliary contacts as normally closed contact
0
Coordination class according to IEC 60947-4-3
Class 1
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
No
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Temperature compensated overload protection
Yes
Rated conditional short-circuit current, type 2, 230 V
0A
Rated operation current at AC-3, 400 V
9A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of electrical connection of main circuit
Screw connection
Suitable for emergency stop
No
Overload release current setting
6.3 - 10A
Rail mounting possible
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Width
45mm
Supporting protocol for other bus systems
No
Height
200mm
Depth
154mm
Supporting protocol for DeviceNet Safety
No
Degree of protection (IP)
IP20
Number of indicator lights
0
External reset possible
No
With fuse
No
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for Data-Highway
No
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet
No
Supporting protocol for SUCONET
No
Supporting protocol for LON
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
From same serie
MSC-D-10-M9(24VDC)/BBA

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Rated operation power at AC-3, 230 V, 3-phase
2.2kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Voltage type for actuating
DC
Rated power, 460 V, 60 Hz, 3-phase
0kW
Ambient temperature, upper operating limit
55°C
Rated control supply voltage Us at DC
24 .. 24V
Power consumption
2.6W
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated operation power at AC-3, 400 V
4kW
Rated operation current Ie
8.5A
Rated conditional short-circuit current, type 2, 400 V
100A
Number of auxiliary contacts as normally open contact
1
Number of command positions
0
Release class
CLASS 10 A
Number of auxiliary contacts as normally closed contact
0
Coordination class according to IEC 60947-4-3
Class 1
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Temperature compensated overload protection
Rated conditional short-circuit current, type 2, 230 V
0A
Rated operation current at AC-3, 400 V
9A
Rated power, 575 V, 60 Hz, 3-phase
0kW
Type of electrical connection of main circuit
Screw connection
Suitable for emergency stop
Overload release current setting
6.3 .. 10A
Rail mounting possible
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Width
45mm
Supporting protocol for other bus systems
Height
200mm
Depth
154mm
Supporting protocol for DeviceNet Safety
Degree of protection (IP)
IP20
Number of indicator lights
0
External reset possible
With fuse
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for Data-Highway
Supporting protocol for Modbus
Supporting protocol for DeviceNet
Supporting protocol for SUCONET
Supporting protocol for LON
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
From same serie
We use cookies to enhance your experience.