Technical specifications

Height260mm
Depth155mm
Width45mm
Rated operation power at AC-3, 400 V4kW
Number of auxiliary contacts as normally closed contact-99999
Number of command positions1
Number of auxiliary contacts as normally open contact-99999
With transformerNo
Supporting protocol for LONNo
Supporting protocol for Data-HighwayNo
Overload release current setting7 - 10A
Rated control supply voltage Us at AC 60HZ230 - 230V
Suitable for emergency stopNo
Rated operation current Ie9A
Rated control supply voltage Us at AC 50HZ230 - 230V
External reset possibleNo
Supporting protocol for CANNo
Rail mounting possibleNo
Supporting protocol for TCP/IPNo
Supporting protocol for ModbusNo
Supporting protocol for INTERBUSNo
Supporting protocol for other bus systemsNo
Supporting protocol for DeviceNetNo
Supporting protocol for PROFIBUSNo
Supporting protocol for ASINo
Supporting protocol for SUCONETNo
Rated control supply voltage Us at DC-99999 - -99999V
Degree of protection (IP)IP20
Supporting protocol for INTERBUS-SafetyNo
Release classCLASS 10
Supporting protocol for SERCOSNo
With short-circuit releaseYes
Number of indicator lights0
With fuseNo
Type of electrical connection of main circuitSpring clamp connection
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET CBANo
Supporting protocol for SafetyBUS pNo
Supporting protocol for Foundation FieldbusNo
Ambient temperature, upper operating limit60°C
Rated power, 575 V, 60 Hz, 3-phase-kW
Rated operation current at AC-3, 400 V9A
Rated operation power at AC-3, 230 V, 3-phase-kW
Type of motor starterOther
Temperature compensated overload protectionNo
Rated power, 460 V, 60 Hz, 3-phase-kW
Rated conditional short-circuit current, type 2, 400 V-A
Coordination class according to IEC 60947-4-3Class 1
Rated conditional short-circuit current, type 1, 480 Y/277 V65000A
Rated conditional short-circuit current, type 2, 230 V-A
Rated conditional short-circuit current, type 1, 600 Y/347 V30000A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

3RA2110-1JH16-1APO

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • SIEMENS

Technical specifications

Height

260mm

Depth

155mm

Width

45mm

Rated operation power at AC-3, 400 V

4kW

Number of auxiliary contacts as normally closed contact

-99999

Number of command positions

1

Number of auxiliary contacts as normally open contact

-99999

With transformer

Supporting protocol for LON

Supporting protocol for Data-Highway

Overload release current setting

7 .. 10A

Rated control supply voltage Us at AC 60HZ

230 .. 230V

Suitable for emergency stop

Rated operation current Ie

9A

Rated control supply voltage Us at AC 50HZ

230 .. 230V

External reset possible

Supporting protocol for CAN

Rail mounting possible

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Supporting protocol for INTERBUS

Supporting protocol for other bus systems

Supporting protocol for DeviceNet

Supporting protocol for PROFIBUS

Supporting protocol for ASI

Supporting protocol for SUCONET

Rated control supply voltage Us at DC

-99999 .. -99999V

Degree of protection (IP)

IP20

Supporting protocol for INTERBUS-Safety

Release class

CLASS 10

Supporting protocol for SERCOS

With short-circuit release

Number of indicator lights

0

With fuse

Type of electrical connection of main circuit

Spring clamp connection

Supporting protocol for DeviceNet Safety

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET IO

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET CBA

Supporting protocol for SafetyBUS p

Supporting protocol for Foundation Fieldbus

Ambient temperature, upper operating limit

60°C

Rated power, 575 V, 60 Hz, 3-phase

-kW

Rated operation current at AC-3, 400 V

9A

Rated operation power at AC-3, 230 V, 3-phase

-kW

Type of motor starter

Other

Temperature compensated overload protection

Rated power, 460 V, 60 Hz, 3-phase

-kW

Rated conditional short-circuit current, type 2, 400 V

-A

Coordination class according to IEC 60947-4-3

Class 1

Rated conditional short-circuit current, type 1, 480 Y/277 V

65000A

Rated conditional short-circuit current, type 2, 230 V

-A

Rated conditional short-circuit current, type 1, 600 Y/347 V

30000A