Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current3A
Built-in depth44mm
Rated voltage230V
Additional equipment possibleYes
Number of protected poles1
Frequency50 - 60Hz
Rated insulation voltage Ui250V
Current limiting class3
Degree of protection (IP)IP20
Release characteristicB
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-core0.75 - 16mm²
Ambient temperature during operating-25 - 70°C
Suitable for flush-mounted installationYes
Connectable conductor cross section multi-wired0.75 - 10mm²
Voltage typeAC
Width in number of modular spacings1
Over voltage category-
Pollution degree2
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407470 | DX3 AUTOM OSIG 1P+N B3 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Rated current

3A

Built-in depth

44mm

Rated voltage

230V

Additional equipment possible

Number of protected poles

1

Frequency

50 .. 60Hz

Rated insulation voltage Ui

250V

Current limiting class

3

Degree of protection (IP)

IP20

Release characteristic

B

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

0.75 .. 16mm²

Ambient temperature during operating

-25 .. 70°C

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 10mm²

Voltage type

AC

Width in number of modular spacings

1

Over voltage category

-

Pollution degree

2

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.