Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Voltage typeAC
Built-in depth44mm
Rated current16A
Rated voltage230V
Frequency50 - 60Hz
Current limiting class3
Pollution degree2
Number of protected poles1
Width in number of modular spacings1
Rated insulation voltage Ui250V
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
Connectable conductor cross section multi-wired0.75 - 10mm²
Suitable for flush-mounted installationYes
Over voltage category-
Release characteristicB
Ambient temperature during operating-25 - 70°C
Connectable conductor cross section solid-core0.75 - 16mm²
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407475 | DX3 AUTOM OSIG 1P+N B16 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 10 KOM
  • LEGRAND

Technical specifications

Voltage type

AC

Built-in depth

44mm

Rated current

16A

Rated voltage

230V

Frequency

50 .. 60Hz

Current limiting class

3

Pollution degree

2

Number of protected poles

1

Width in number of modular spacings

1

Rated insulation voltage Ui

250V

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 10mm²

Suitable for flush-mounted installation

Over voltage category

-

Release characteristic

B

Ambient temperature during operating

-25 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 16mm²

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.