Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Number of protected poles1
Number of poles (total)2
Release characteristicC
Rated insulation voltage Ui250V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeAC
Rated current20A
Rated voltage230V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Concurrently switching neutral conductorYes
Suitable for flush-mounted installationYes
Current limiting class3
Pollution degree2
Over voltage category-
Connectable conductor cross section multi-wired0.75 - 10mm²
Connectable conductor cross section solid-core0.75 - 16mm²
Degree of protection (IP)IP20
Width in number of modular spacings1
Ambient temperature during operating-25 - 70°C
Built-in depth44mm
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

407743 | DX3 AUTOM OSIG 1P+N C20 10KA

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • LEGRAND

Technical specifications

Number of protected poles

1

Number of poles (total)

2

Release characteristic

C

Rated insulation voltage Ui

250V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

AC

Rated current

20A

Rated voltage

230V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Current limiting class

3

Pollution degree

2

Over voltage category

-

Connectable conductor cross section multi-wired

0.75 .. 10mm²

Connectable conductor cross section solid-core

0.75 .. 16mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 70°C

Built-in depth

44mm

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.