Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui500V
Number of poles (total)2
Number of protected poles2
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated voltage-V
Power loss-W
Built-in depth69mm
Rated impulse withstand voltage Uimp6kV
Release characteristicOther
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated current6.3A
Current limiting class-
Additional equipment possibleYes
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Over voltage category4
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-40 - 70°C
Pollution degree3
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Width in number of modular spacings2.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDA382799R0361 | M302P-D6,3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Professional worker

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Number of poles (total)

2

Number of protected poles

2

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated voltage

-V

Power loss

-W

Built-in depth

69mm

Rated impulse withstand voltage Uimp

6kV

Release characteristic

Other

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated current

6.3A

Current limiting class

-

Additional equipment possible

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Over voltage category

4

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-40 .. 70°C

Pollution degree

3

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Width in number of modular spacings

2.0