Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Explosion-proofNo
Width in number of modular spacings2.0
Current limiting class3
Pollution degree3
Release characteristicC
Rated current4A
Rated voltage440V
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Over voltage category3
Voltage typeOther
Built-in depth69mm
Power loss2.96W
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Degree of protection (IP)IP20
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272065R0044 | S202MT-C4UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Explosion-proof

Width in number of modular spacings

2.0

Current limiting class

3

Pollution degree

3

Release characteristic

C

Rated current

4A

Rated voltage

440V

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Over voltage category

3

Voltage type

Other

Built-in depth

69mm

Power loss

2.96W

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Degree of protection (IP)

IP20

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.