Aleta.hr
Main Product Image

2CDS272065R0217 | S202MT-K1UC

Code: 2015552

ManufacturerABB
Catalog number2CDS272065R0217
EAN code4013614449017

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)2
Rated current1A
Power loss2.66W
Rated insulation voltage Ui440V
Number of protected poles2
Release characteristicK
Rated voltage440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Frequency50 - 60Hz
Voltage typeOther
Current limiting class3
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Over voltage category3
Explosion-proofNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Degree of protection (IP)IP20
Width in number of modular spacings2.0
Pollution degree3
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272065R0217 | S202MT-K1UC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

2

Rated current

1A

Power loss

2.66W

Rated insulation voltage Ui

440V

Number of protected poles

2

Release characteristic

K

Rated voltage

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Frequency

50 .. 60Hz

Voltage type

Other

Current limiting class

3

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Explosion-proof

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

2.0

Pollution degree

3

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 55°C