Technical specifications

Rated voltage440V
Rated insulation voltage Ui440V
Built-in depth69mm
Frequency50 - 60Hz
Release characteristicK
Rated current32A
Voltage typeOther
Degree of protection (IP)IP20
Current limiting class3
Power loss7.4W
Explosion-proofNo
Over voltage category3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of poles (total)2
Width in number of modular spacings2.0
Concurrently switching neutral conductorNo
Number of protected poles2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Pollution degree3
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272065R0537 | S202MT-K32UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

440V

Rated insulation voltage Ui

440V

Built-in depth

69mm

Frequency

50 .. 60Hz

Release characteristic

K

Rated current

32A

Voltage type

Other

Degree of protection (IP)

IP20

Current limiting class

3

Power loss

7.4W

Explosion-proof

Over voltage category

3

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of poles (total)

2

Width in number of modular spacings

2.0

Concurrently switching neutral conductor

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Pollution degree

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²