Aleta.hr
Main Product Image

2CDS272065R0634 | S202MT-C63UC

Code: 2015575

ManufacturerABB
Catalog number2CDS272065R0634
EAN code4013614465307

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Number of poles (total)2
Rated voltage440V
Rated current63A
Number of protected poles2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Power loss11.18W
Rated insulation voltage Ui440V
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Current limiting class3
Release characteristicC
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Over voltage category3
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Width in number of modular spacings2.0
Degree of protection (IP)IP20
Explosion-proofNo
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Connectable conductor cross section solid-core0.75 - 35mm²
Pollution degree3
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272065R0634 | S202MT-C63UC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Number of poles (total)

2

Rated voltage

440V

Rated current

63A

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Power loss

11.18W

Rated insulation voltage Ui

440V

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Current limiting class

3

Release characteristic

C

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Over voltage category

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Width in number of modular spacings

2.0

Degree of protection (IP)

IP20

Explosion-proof

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Connectable conductor cross section solid-core

0.75 .. 35mm²

Pollution degree

3

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.