Aleta.hr
Main Product Image

2CDS273337R0388 | SU203M-Z7

Code: 2015578

ManufacturerABB
Catalog number2CDS273337R0388
EAN code4013614446948

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles3
Rated current7A
Release characteristicZ
Number of poles (total)3
Rated voltage480V
Built-in depth69mm
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss4.5W
Voltage typeOther
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Current limiting class3
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Flush-mounted installationNo
Over voltage category3
Width in number of modular spacings3.0
Additional equipment possibleYes
Pollution degree3
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS273337R0388 | SU203M-Z7

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of protected poles

3

Rated current

7A

Release characteristic

Z

Number of poles (total)

3

Rated voltage

480V

Built-in depth

69mm

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

4.5W

Voltage type

Other

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Flush-mounted installation

Over voltage category

3

Width in number of modular spacings

3.0

Additional equipment possible

Pollution degree

3

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.