Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Current limiting class3
Built-in depth69mm
Frequency50 - 60Hz
Width in number of modular spacings4.0
Rated current2A
Release characteristicC
Number of protected poles4
Pollution degree3
Voltage typeOther
Additional equipment possibleYes
Power loss5.8W
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Rated voltage440V
Flush-mounted installationNo
Rated insulation voltage Ui440V
Number of poles (total)4
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274065R0024 | S204MT-C2UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Current limiting class

3

Built-in depth

69mm

Frequency

50 .. 60Hz

Width in number of modular spacings

4.0

Rated current

2A

Release characteristic

C

Number of protected poles

4

Pollution degree

3

Voltage type

Other

Additional equipment possible

Power loss

5.8W

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated voltage

440V

Flush-mounted installation

Rated insulation voltage Ui

440V

Number of poles (total)

4

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.