Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Rated voltage440V
Built-in depth69mm
Frequency50 - 60Hz
Voltage typeOther
Rated current4A
Power loss5.92W
Number of protected poles4
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Pollution degree3
Over voltage category3
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 55°C
Current limiting class3
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Explosion-proofNo
Width in number of modular spacings4.0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274065R0044 | S204MT-C4UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Rated voltage

440V

Built-in depth

69mm

Frequency

50 .. 60Hz

Voltage type

Other

Rated current

4A

Power loss

5.92W

Number of protected poles

4

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Pollution degree

3

Over voltage category

3

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Current limiting class

3

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Explosion-proof

Width in number of modular spacings

4.0

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.