Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)4
Number of protected poles4
Built-in depth69mm
Release characteristicC
Rated impulse withstand voltage Uimp4kV
Rated current50A
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated voltage440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated insulation voltage Ui440V
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Frequency50 - 60Hz
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Current limiting class3
Power loss17.76W
Over voltage category3
Pollution degree3
Additional equipment possibleYes
Degree of protection (IP)IP20
Width in number of modular spacings4.0
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274065R0504 | S204MT-C50UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Number of poles (total)

4

Number of protected poles

4

Built-in depth

69mm

Release characteristic

C

Rated impulse withstand voltage Uimp

4kV

Rated current

50A

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated insulation voltage Ui

440V

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Frequency

50 .. 60Hz

Flush-mounted installation

Concurrently switching neutral conductor

Current limiting class

3

Power loss

17.76W

Over voltage category

3

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20

Width in number of modular spacings

4.0

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.