Aleta.hr
Main Product Image

2CDS274065R0527 | S204MT-K30UC

Code: 2015606

ManufacturerRAZNO
Catalog number2CDS274065R0527
Type
EAN code4013614447426

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Number of poles (total)

4

Current limiting class

3

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated voltage

440V

Rated current

30A

Number of protected poles

4

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Power loss

13.04W

Frequency

50 - 60Hz

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

No

Over voltage category

3

Pollution degree

3

Flush-mounted installation

No

Width in number of modular spacings

4.0

Additional equipment possible

Yes

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 55°C

Connectable conductor cross section multi-wired

0.75 - 25mm²

Explosion-proof

No

Connectable conductor cross section solid-core

0.75 - 35mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

2CDS274065R0527 | S204MT-K30UC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

K

Number of poles (total)

4

Current limiting class

3

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated voltage

440V

Rated current

30A

Number of protected poles

4

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Power loss

13.04W

Frequency

50 .. 60Hz

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

3

Flush-mounted installation

Width in number of modular spacings

4.0

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.