  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency0 - 60Hz
Voltage typeAC/DC
Built-in depth69mm
Release characteristicK
Rated current3A
Rated voltage480V
Power loss6.4W
Concurrently switching neutral conductorNo
Width in number of modular spacings4
Number of protected poles4
Number of poles (total)4
Rated insulation voltage Ui440V
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Explosion-proofNo
Over voltage category3
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Suitable for flush-mounted installationNo
Current limiting class3
Ambient temperature during operating-25 - 55°C
Degree of protection (IP)IP20
Connectable conductor cross section solid-core0 - 35mm²
Connectable conductor cross section multi-wired0 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274337R0317 | SU204M-K3

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

0 .. 60Hz

Voltage type

AC/DC

Built-in depth

69mm

Release characteristic

K

Rated current

3A

Rated voltage

480V

Power loss

6.4W

Concurrently switching neutral conductor

Width in number of modular spacings

4

Number of protected poles

4

Number of poles (total)

4

Rated insulation voltage Ui

440V

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Explosion-proof

Over voltage category

3

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Suitable for flush-mounted installation

Current limiting class

3

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

0 .. 35mm²

Connectable conductor cross section multi-wired

0 .. 25mm²