Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated insulation voltage Ui440V
Release characteristicK
Frequency0 - 60Hz
Rated voltage480V
Rated current5A
Current limiting class3
Built-in depth69mm
Over voltage category3
Degree of protection (IP)IP20
Pollution degree3
Number of protected poles4
Suitable for flush-mounted installationNo
Width in number of modular spacings4
Power loss5.2W
Explosion-proofNo
Concurrently switching neutral conductorNo
Number of poles (total)4
Flush-mounted installationNo
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Additional equipment possibleYes
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274337R0357 | SU204M-K5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated insulation voltage Ui

440V

Release characteristic

K

Frequency

0 .. 60Hz

Rated voltage

480V

Rated current

5A

Current limiting class

3

Built-in depth

69mm

Over voltage category

3

Degree of protection (IP)

IP20

Pollution degree

3

Number of protected poles

4

Suitable for flush-mounted installation

Width in number of modular spacings

4

Power loss

5.2W

Explosion-proof

Concurrently switching neutral conductor

Number of poles (total)

4

Flush-mounted installation

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Additional equipment possible

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.