Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated fault current0.03A
Current limiting class3
Rated voltage230V
Built-in depth35mm
Pollution degree2
Rated insulation voltage Ui500V
Connectable conductor cross section solid-core- - -mm²
Power loss9.1W
Frequency50/60 Hz
Over voltage category3
Rated short-circuit breaking capacity according to IEC 60947-210kA
Leakage current typeA
Rated current40A
Degree of protection (IP)IP20
Concurrently switching neutral conductorYes
With interlocking deviceNo
Number of protected poles1
Surge current capacity-kA
Connectable conductor cross section multi-wired0.75 - 16mm²
Width in number of modular spacings2
Release characteristicB
Anti-nuisance tripping versionNo
Number of poles (total)2
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255188R1405 | DS201T B40 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated fault current

0.03A

Current limiting class

3

Rated voltage

230V

Built-in depth

35mm

Pollution degree

2

Rated insulation voltage Ui

500V

Connectable conductor cross section solid-core

- .. -mm²

Power loss

9.1W

Frequency

50/60 Hz

Over voltage category

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Leakage current type

A

Rated current

40A

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

With interlocking device

Number of protected poles

1

Surge current capacity

-kA

Connectable conductor cross section multi-wired

0.75 .. 16mm²

Width in number of modular spacings

2

Release characteristic

B

Anti-nuisance tripping version

Number of poles (total)

2

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.