Technical specifications

Built-in depth69mm
Rated fault current0.1A
Rated voltage415V
Rated insulation voltage Ui500V
Rated current6A
Voltage typeAC
Release characteristicB
Current limiting class3
Pollution degree2
Leakage current typeA
Power loss7.5W
Over voltage category3
Width in number of modular spacings4
Surge current capacity0.25kA
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wired25 - 25mm²
Concurrently switching neutral conductorYes
Flush-mounted installationNo
Degree of protection (IP)IP2X
Number of poles (total)4
Frequency50/60 Hz
Connectable conductor cross section solid-core25 - 25mm²
With interlocking deviceYes
Disconnection characteristicUndelayed
Rated short-circuit breaking capacity according to IEC 60947-210kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity according to EN 610096kA
Number of protected poles3
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 61009-16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR256140R2065 | DS203NC B6 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated fault current

0.1A

Rated voltage

415V

Rated insulation voltage Ui

500V

Rated current

6A

Voltage type

AC

Release characteristic

B

Current limiting class

3

Pollution degree

2

Leakage current type

A

Power loss

7.5W

Over voltage category

3

Width in number of modular spacings

4

Surge current capacity

0.25kA

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

25 .. 25mm²

Concurrently switching neutral conductor

Flush-mounted installation

Degree of protection (IP)

IP2X

Number of poles (total)

4

Frequency

50/60 Hz

Connectable conductor cross section solid-core

25 .. 25mm²

With interlocking device

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity according to EN 61009

6kA

Number of protected poles

3

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.