Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeOther
Power loss-W
Number of poles (total)2
Release characteristicOther
Current limiting class-
Rated current16A
Number of protected poles2
Rated voltage-V
Built-in depth69mm
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Explosion-proofNo
Degree of protection (IP)IP20
Width in number of modular spacings2.0
Over voltage category4
Pollution degree3
Ambient temperature during operating-40 - 70°C
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDA382799R0161 | M302P-D16

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Power loss

-W

Number of poles (total)

2

Release characteristic

Other

Current limiting class

-

Rated current

16A

Number of protected poles

2

Rated voltage

-V

Built-in depth

69mm

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Explosion-proof

Degree of protection (IP)

IP20

Width in number of modular spacings

2.0

Over voltage category

4

Pollution degree

3

Ambient temperature during operating

-40 .. 70°C

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.