Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicOther
Number of protected poles3
Built-in depth69mm
Rated current12.5A
Voltage typeOther
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated voltage-V
Number of poles (total)3
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Power loss-W
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp6kV
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Width in number of modular spacings3.0
Flush-mounted installationNo
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Pollution degree3
Over voltage category4
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Explosion-proofNo
Degree of protection (IP)IP20
Ambient temperature during operating-40 - 70°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDA383799R0491 | M303P-D12,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Other

Number of protected poles

3

Built-in depth

69mm

Rated current

12.5A

Voltage type

Other

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated voltage

-V

Number of poles (total)

3

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Power loss

-W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

6kV

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Width in number of modular spacings

3.0

Flush-mounted installation

Concurrently switching neutral conductor

Additional equipment possible

Pollution degree

3

Over voltage category

4

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Explosion-proof

Degree of protection (IP)

IP20

Ambient temperature during operating

-40 .. 70°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.