Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicOther
Rated current0.5A
Number of poles (total)3
Rated voltage-V
Built-in depth69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V100kA
Power loss-W
Number of protected poles3
Rated insulation voltage Ui500V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Voltage typeOther
Frequency50 - 60Hz
Current limiting class-
Rated impulse withstand voltage Uimp6kV
Pollution degree3
Over voltage category4
Concurrently switching neutral conductorNo
Width in number of modular spacings3.0
Additional equipment possibleYes
Ambient temperature during operating-40 - 70°C
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0.75 - 25mm²
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDA383799R0981 | M303P-D0,5

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Other

Rated current

0.5A

Number of poles (total)

3

Rated voltage

-V

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

100kA

Power loss

-W

Number of protected poles

3

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Voltage type

Other

Frequency

50 .. 60Hz

Current limiting class

-

Rated impulse withstand voltage Uimp

6kV

Pollution degree

3

Over voltage category

4

Concurrently switching neutral conductor

Width in number of modular spacings

3.0

Additional equipment possible

Ambient temperature during operating

-40 .. 70°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.