Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree3
Built-in depth69mm
Number of protected poles1
Rated voltage220V
Frequency50 - 60Hz
Explosion-proofNo
Power loss1.54W
Degree of protection (IP)IP20
Width in number of modular spacings1.0
Release characteristicC
Rated current8A
Rated insulation voltage Ui440V
Current limiting class3
Over voltage category3
Voltage typeOther
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Ambient temperature during operating-25 - 55°C
Number of poles (total)1
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271065R0084 | S201MT-C8UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

3

Built-in depth

69mm

Number of protected poles

1

Rated voltage

220V

Frequency

50 .. 60Hz

Explosion-proof

Power loss

1.54W

Degree of protection (IP)

IP20

Width in number of modular spacings

1.0

Release characteristic

C

Rated current

8A

Rated insulation voltage Ui

440V

Current limiting class

3

Over voltage category

3

Voltage type

Other

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

Additional equipment possible

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

1

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.