Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated voltage220V
Rated current6A
Voltage typeOther
Number of protected poles1
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree3
Width in number of modular spacings1.0
Power loss1.77W
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Current limiting class3
Explosion-proofNo
Release characteristicK
Connectable conductor cross section solid-core0.75 - 35mm²
Connectable conductor cross section multi-wired0.75 - 25mm²
Ambient temperature during operating-25 - 55°C
Frequency50 - 60Hz
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271065R0377 | S201MT-K6UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated voltage

220V

Rated current

6A

Voltage type

Other

Number of protected poles

1

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

3

Width in number of modular spacings

1.0

Power loss

1.77W

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Current limiting class

3

Explosion-proof

Release characteristic

K

Connectable conductor cross section solid-core

0.75 .. 35mm²

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Frequency

50 .. 60Hz

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.