Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Current limiting class3
Built-in depth69mm
Release characteristicK
Rated current13A
Over voltage category3
Rated voltage220V
Pollution degree3
Rated insulation voltage Ui440V
Concurrently switching neutral conductorNo
Number of protected poles1
Width in number of modular spacings1.0
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Explosion-proofNo
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Degree of protection (IP)IP20
Power loss2.29W
Number of poles (total)1
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Ambient temperature during operating-25 - 55°C
Voltage typeOther
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271065R0447 | S201MT-K13UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Current limiting class

3

Built-in depth

69mm

Release characteristic

K

Rated current

13A

Over voltage category

3

Rated voltage

220V

Pollution degree

3

Rated insulation voltage Ui

440V

Concurrently switching neutral conductor

Number of protected poles

1

Width in number of modular spacings

1.0

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Explosion-proof

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Degree of protection (IP)

IP20

Power loss

2.29W

Number of poles (total)

1

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Ambient temperature during operating

-25 .. 55°C

Voltage type

Other

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.