Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeOther
Rated current63A
Frequency50 - 60Hz
Rated voltage220V
Current limiting class3
Over voltage category3
Power loss5.45W
Width in number of modular spacings1.0
Explosion-proofNo
Pollution degree3
Rated insulation voltage Ui440V
Connectable conductor cross section solid-core0.75 - 35mm²
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Number of protected poles1
Ambient temperature during operating-25 - 55°C
Degree of protection (IP)IP20
Flush-mounted installationNo
Connectable conductor cross section multi-wired0.75 - 25mm²
Release characteristicB
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Number of poles (total)1
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271065R0635 | S201MT-B63UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

Other

Rated current

63A

Frequency

50 .. 60Hz

Rated voltage

220V

Current limiting class

3

Over voltage category

3

Power loss

5.45W

Width in number of modular spacings

1.0

Explosion-proof

Pollution degree

3

Rated insulation voltage Ui

440V

Connectable conductor cross section solid-core

0.75 .. 35mm²

Additional equipment possible

Concurrently switching neutral conductor

Number of protected poles

1

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Flush-mounted installation

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Release characteristic

B

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Number of poles (total)

1

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA