  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicC
Number of protected poles2
Rated current3A
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated voltage440V
Rated insulation voltage Ui484V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Built-in depth69mm
Voltage typeAC/DC
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Flush-mounted installationNo
Current limiting class3
Pollution degree3
Concurrently switching neutral conductorNo
Over voltage category3
Width in number of modular spacings2
Additional equipment possibleNo
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Explosion-proofNo
Connectable conductor cross section solid-core0,75 - 35mm²
Connectable conductor cross section multi-wired0,75 - 25mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272065R0034 | S202MT-C3UC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Number of protected poles

2

Rated current

3A

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated voltage

440V

Rated insulation voltage Ui

484V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Built-in depth

69mm

Voltage type

AC/DC

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Current limiting class

3

Pollution degree

3

Concurrently switching neutral conductor

Over voltage category

3

Width in number of modular spacings

2

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Explosion-proof

Connectable conductor cross section solid-core

0,75 .. 35mm²

Connectable conductor cross section multi-wired

0,75 .. 25mm²

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.