Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui440V
Voltage typeOther
Current limiting class3
Built-in depth69mm
Rated current0.2A
Release characteristicK
Frequency50 - 60Hz
Rated voltage440V
Over voltage category3
Explosion-proofNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Width in number of modular spacings2.0
Flush-mounted installationNo
Number of protected poles2
Number of poles (total)2
Pollution degree3
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core0.75 - 35mm²
Ambient temperature during operating-25 - 55°C
Power loss2.22W
Concurrently switching neutral conductorNo
Additional equipment possibleYes
Connectable conductor cross section multi-wired0.75 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272065R0087 | S202MT-K0.2UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

440V

Voltage type

Other

Current limiting class

3

Built-in depth

69mm

Rated current

0.2A

Release characteristic

K

Frequency

50 .. 60Hz

Rated voltage

440V

Over voltage category

3

Explosion-proof

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Width in number of modular spacings

2.0

Flush-mounted installation

Number of protected poles

2

Number of poles (total)

2

Pollution degree

3

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

0.75 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Power loss

2.22W

Concurrently switching neutral conductor

Additional equipment possible

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.