Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current60A
Pollution degree3
Current limiting class3
Voltage typeOther
Built-in depth69mm
Rated voltage440V
Width in number of modular spacings2.0
Release characteristicZ
Frequency50 - 60Hz
Over voltage category3
Rated insulation voltage Ui440V
Explosion-proofNo
Degree of protection (IP)IP20
Number of poles (total)2
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Power loss11.14W
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Connectable conductor cross section solid-core0.75 - 35mm²
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272065R0588 | S202MT-Z60UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated current

60A

Pollution degree

3

Current limiting class

3

Voltage type

Other

Built-in depth

69mm

Rated voltage

440V

Width in number of modular spacings

2.0

Release characteristic

Z

Frequency

50 .. 60Hz

Over voltage category

3

Rated insulation voltage Ui

440V

Explosion-proof

Degree of protection (IP)

IP20

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Power loss

11.14W

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Connectable conductor cross section solid-core

0.75 .. 35mm²

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.