Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency50 - 60Hz
Rated voltage440V
Rated current20A
Voltage typeOther
Built-in depth69mm
Rated insulation voltage Ui440V
Width in number of modular spacings4.0
Concurrently switching neutral conductorNo
Release characteristicC
Degree of protection (IP)IP20
Explosion-proofNo
Power loss9.04W
Pollution degree3
Over voltage category3
Number of protected poles4
Connectable conductor cross section solid-core0.75 - 35mm²
Current limiting class3
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Connectable conductor cross section multi-wired0.75 - 25mm²
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274065R0204 | S204MT-C20UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Frequency

50 .. 60Hz

Rated voltage

440V

Rated current

20A

Voltage type

Other

Built-in depth

69mm

Rated insulation voltage Ui

440V

Width in number of modular spacings

4.0

Concurrently switching neutral conductor

Release characteristic

C

Degree of protection (IP)

IP20

Explosion-proof

Power loss

9.04W

Pollution degree

3

Over voltage category

3

Number of protected poles

4

Connectable conductor cross section solid-core

0.75 .. 35mm²

Current limiting class

3

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.