Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Power loss7.08W
Pollution degree3
Rated current6A
Width in number of modular spacings4.0
Explosion-proofNo
Frequency50 - 60Hz
Release characteristicK
Rated voltage440V
Number of protected poles4
Rated insulation voltage Ui440V
Degree of protection (IP)IP20
Current limiting class3
Over voltage category3
Voltage typeOther
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0.75 - 25mm²
Flush-mounted installationNo
Connectable conductor cross section solid-core0.75 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274065R0377 | S204MT-K6UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Power loss

7.08W

Pollution degree

3

Rated current

6A

Width in number of modular spacings

4.0

Explosion-proof

Frequency

50 .. 60Hz

Release characteristic

K

Rated voltage

440V

Number of protected poles

4

Rated insulation voltage Ui

440V

Degree of protection (IP)

IP20

Current limiting class

3

Over voltage category

3

Voltage type

Other

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0.75 .. 25mm²

Flush-mounted installation

Connectable conductor cross section solid-core

0.75 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

4

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.