  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage480V
Voltage typeAC/DC
Built-in depth69mm
Rated current6A
Width in number of modular spacings4
Release characteristicC
Pollution degree3
Current limiting class3
Rated insulation voltage Ui440V
Over voltage category3
Frequency0 - 60Hz
Ambient temperature during operating-25 - 55°C
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Rated impulse withstand voltage Uimp4kV
Connectable conductor cross section solid-core0 - 35mm²
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of protected poles4
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274337R0064 | SU204M-C6

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

480V

Voltage type

AC/DC

Built-in depth

69mm

Rated current

6A

Width in number of modular spacings

4

Release characteristic

C

Pollution degree

3

Current limiting class

3

Rated insulation voltage Ui

440V

Over voltage category

3

Frequency

0 .. 60Hz

Ambient temperature during operating

-25 .. 55°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Rated impulse withstand voltage Uimp

4kV

Connectable conductor cross section solid-core

0 .. 35mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of protected poles

4

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.