Aleta.hr
Main Product Image

2CDS274337R0064 | SU204M-C6

Code: 2016407

ManufacturerABB
Catalog number2CDS274337R0064
EAN code4016779931502

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V-kA
Number of poles (total)4
Rated current6A
Rated insulation voltage Ui440V
Release characteristicC
Number of protected poles4
Frequency0 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Voltage typeAC/DC
Pollution degree3
Rated voltage480V
Additional equipment possibleYes
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V11.2kA
Suitable for flush-mounted installationNo
Current limiting class3
Over voltage category3
Width in number of modular spacings4
Degree of protection (IP)IP20
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core0 - 35mm²
Built-in depth69mm
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274337R0064 | SU204M-C6

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

-kA

Number of poles (total)

4

Rated current

6A

Rated insulation voltage Ui

440V

Release characteristic

C

Number of protected poles

4

Frequency

0 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC/DC

Pollution degree

3

Rated voltage

480V

Additional equipment possible

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

11.2kA

Suitable for flush-mounted installation

Current limiting class

3

Over voltage category

3

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

0 .. 35mm²

Built-in depth

69mm

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.